Part Number: ETI0005-1016AD
2000 VA Rugged NEMA UPS


ETI0005-1016AD Standard NEMA Enclosure PowerStation™Isolated UPS
2.0 KVA, 120VAC/120VAC, 50/60Hz with Isolation and Alarm Summary
120 Minute Battery Back Up @ 8 Amps

The field proven PowerStation UPS line is ideally suited for military, industrial and telecommunications applications requiring rugged rack or table mount and/or portable construction, high reliability, compact size and light weight design. The heavy duty chassis occupies minimal space while delivering up to 2000 VA of clean, uninterruptible power. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. An internal transformer bay accommodates the input isolation transformer with provisions for both domestic and optional international voltages for ratings up to 2000 VA. The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. Various optional power distribution controls are available which mount internally or remotely.

Locking connectors for the input and output power are available as options. Multiple input and output power panel options are also available. A washable intake air filter and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The exhaust air is diverted out side vents. An external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The status D shell connector provides signals to interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

Overall, the PowerStation line is uniquely qualified for critical industrial, shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

ETI0005-1016AD

AC OUTPUT

Output voltage:

120 VAC true sinewave std, optional outputs

Output rating: UPS

2000 VA

Non-linear load capacity:

Up to 100% non-linear load capability

Output voltage regulation: UPS

± 3.0% static, ± 4.0% dynamic (0 to 50% load step)

Overload surge capacity:

110% for 10 minutes; 125% for 30 seconds

Harmonic distortion:

Less than 5.0% into 100% non-linear load

Output frequency: UPS

60 or 50 Hz ± 2.5% when synchronized to input frequency
± 1.0% when input frequency is out of range or not present

Operational status:

Status, load and battery (15) LED’s, adjustable level,
+90 dB audible alarm w/on/off

AC INPUT

Input voltage selection:

120/240 VAC standard 50/60 Hz

Input voltage tolerance: UPS

+15% -25% of nominal input rating

Input/output isolation:

Up to 120 dB common mode attenuation

Input transient suppression:

Meets ANSI C62.41 1980, IEEE 587 standards

Input control/protection:

Guarded 2 pole switch (S1) w/panel mounted fuse (F2)

Input power connection:

Terminal Block

BATTERY

Type:

Maintenance free immobilized electrolyte, 48VDC
Flame retardant materials (Oxygen Index 28+)

Battery life:

Rated for continuous service life of 5 years

DC protection:

Guarded fuse (F1)

Battery expansion:
Dimensions

Up to 24 hours w/ Battery Extension Modules
Height 24” Width 20” Depth 17.00”

DISTRIBUTION PANEL

Output circuits:

Terminal Block

Output control:

Optional panel switches or breakers or PDU

Output receptacles:

Terminal Block

MECHANICAL

Alternate Mounting Options:

Wall

Audible noise:

Less than 47 dB @ 5.0 ft., ANSI "A" scale

Cooling type:

High capacity, positive pressure, forced air

Air Intake Filter

Washable metal filter media, others optional

Dimensions-Ups Nema Enclosure

Height 36” Width 30” Depth 17.10”

ENVIRONMENTAL

Storage temperature:

 -4° to 122° F ambient  (-20° to 50° C)

Operating temperature:

32° to 113° F ambient  (0° to 45° C)

Operating humidity:

0 to 95% relative humidity (non-condensing)

Storage elevation:

Up to 40,000 ft (12,192 m), higher optionally

Operating elevation:

Up to 10,000 ft (3,048 m), higher optionally

STANDARDS

United States:

Meets UL-1778 standard for UPS equipment,
MIL STDs 810, 454 & 1399 Shock/Vib/Electrical

Canada:

CSA C22.2 No. 107 UPS safety requirements

EMI Protection:

EMI/RFI FCC, Class A, opt MIL STDs 461 & 462

OPTIONS AVAILABLE

 

Rack mount power ratings to 6kVA, Dual Source Input, Battery Expansion Units, Power Distribution Units, Software Interfaces and Transport Cases

Request Product Information
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466